NPRR1282
Summary
| Title | Ancillary Service Duration under Real-Time Co-Optimization |
|---|---|
| Next Group | |
| Next Step | |
| Status | Approved on 07/31/2025 |
| Effective Dates |
12/05/2025
|
Action
| Date | Gov Body | Action Taken | Next Steps |
|---|---|---|---|
| 07/31/2025 | PUCT | Approved | |
| 06/24/2025 | BOARD | Recommended for Approval | PUCT for consideration |
| 05/28/2025 | TAC | Recommended for Approval | Board for consideration |
| 05/14/2025 | PRS | Recommended for Approval | TAC for consideration |
Voting Record
| Date | Gov Body | Motion | Result |
|---|---|---|---|
| 07/31/2025 | PUCT | To approve NPRR1282 and accompanying ERCOT Market Impact Statement as presented in Project No. 54445, Review of Protocols Adopted by the Independent Organization | Passed |
| 06/24/2025 | BOARD | To recommend approval of NPRR1282 as recommended by TAC in the 5/28/25 TAC Report | Passed |
| 05/28/2025 | TAC | To recommend approval of NPRR1282 as recommended by PRS in the 5/14/25 PRS Report | Passed |
| 05/14/2025 | PRS | To grant NPRR1282 Urgent status; to recommend approval of NPRR1282 as submitted; and to forward to TAC NPRR1282 and the 4/29/25 Impact Analysis | Passed |
Background
| Status: | Approved |
|---|---|
| Date Posted: | Apr 29, 2025 |
| Sponsor: | ERCOT |
| Urgent: | Yes |
| Sections: | 2.2, 5.5.2, 8.1.1.2.1.1, 8.1.1.2.1.2, 8.1.1.2.1.3, 8.1.1.3.1, 8.1.1.3.2, and 8.1.1.3.4 |
| Description: | This Nodal Protocol Revision Request (NPRR) makes changes to the duration requirements for the following Ancillary Services in preparation for Real-Time Co-optimization plus Batteries (RTC+B): Updates duration requirements for Regulation Service and Responsive Reserve (RRS) to thirty minutes; and updates duration requirement for ERCOT Contingency Reserve Service (ECRS) to one hour. This NPRR also updates the requirement for Reliability Unit Commitment (RUC) studies to use a one-hour duration for all Ancillary Service types, excluding Fast Frequency Response (FFR). The changes proposed in this NPRR have no system impacts because these Ancillary Service durations are being incorporated as parameters in the current RTC+B business requirements. |
| Reason: | General system and/or process improvement(s) |
Key Documents
Apr 29, 2025 - docx - 81.1 KB
Apr 29, 2025 - docx - 30.8 KB
May 4, 2025 - docx - 158.8 KB
May 7, 2025 - doc - 58 KB
May 12, 2025 - docx - 25.7 KB
May 12, 2025 - docx - 166.4 KB
May 13, 2025 - docx - 65.2 KB
May 13, 2025 - docx - 25.5 KB
May 15, 2025 - xls - 113 KB
May 15, 2025 - xls - 141.5 KB
May 15, 2025 - docx - 85.4 KB
May 27, 2025 - docx - 25.1 KB
Jun 2, 2025 - xls - 109.5 KB
Jun 2, 2025 - docx - 94.6 KB
Jun 18, 2025 - docx - 164.8 KB
Jun 18, 2025 - docx - 167.9 KB
Jun 19, 2025 - docx - 37.9 KB
Jun 20, 2025 - docx - 31 KB
Jun 23, 2025 - docx - 26.7 KB
Jun 24, 2025 - docx - 95.5 KB
Aug 4, 2025 - docx - 95.5 KB