NPRR214
Summary
| Title | Wind-powered Generation Resource (WGR) High Sustained Limit (HSL) Update Process |
|---|---|
| Next Group | |
| Next Step | |
| Status | Approved on 05/18/2010 |
| Effective Dates |
12/01/2010
or per the Nodal Protocol Transition Plan http://www.ercot.com/mktrules/protocols (06/01/10 Nodal Protocols Library) |
Action
| Date | Gov Body | Action Taken | Next Steps |
|---|---|---|---|
| 04/22/2010 | PRS | Recommended for Approval | TAC consideration of NPRR214 |
| 05/18/2010 | BOARD | Approved | |
| 05/06/2010 | TAC | Recommended for Approval | ERCOT Board consideration of NPRR214 |
| 03/25/2010 | PRS | Recommended for Approval | PRS Impact Analysis review |
Voting Record
| Date | Gov Body | Motion | Result |
|---|---|---|---|
| 04/22/2010 | PRS | To endorse and forward the 3/25/10 PRS Report and Impact Analysis for NPRR214 to TAC | Passed |
| 05/18/2010 | BOARD | To approve NPRR214 as recommended by TAC in the 5/6/10 TAC Report. | Passed |
| 05/06/2010 | TAC | To recommend approval of NPRR214 as recommended by PRS in the 4/22/10 PRS Report. | Passed |
| 03/25/2010 | PRS | To recommend approval of NPRR214 as amended by the 3/16/10 Luminant comments. | Passed |
Background
| Status: | Approved |
|---|---|
| Date Posted: | Mar 12, 2010 |
| Sponsor: | Wind Coalition |
| Urgent: | No |
| Sections: | 6.5.5.2 |
| Description: | This Nodal Protocol Revision Request (NPRR) establishes the specific timing of the WGR’s HSL update to ERCOT and specifies that, when not curtailed, the WGR’s HSL should equal the WGR’s current meter reading. |
| Reason: | This NPRR will provide a clear and consistent mechanism to signal the need for active action by WGRs to curtail their output when ERCOT is Dispatching them below their HSL. The current wording does not specify the timing of the HSL updates and continuous updates to ERCOT would be expected. If the updates change every cycle, then there is no way of knowing the HSL value that ERCOT is using in the Security-Constrained Economic Dispatch (SCED) calculation for Base Points. Thus the curtailment trigger of comparing the ordered Base Point to the HSL will not be consistently applied. This revision insures that the HSL used by SCED is known to the WGR. |