NPRR1214
Summary
| Title | Reliability Deployment Price Adder Fix to Provide Locational Price Signals, Reduce Uplift and Risk |
|---|---|
| Next Group | |
| Next Step | |
| Status | Approved on 11/05/2026 |
Action
| Date | Gov Body | Action Taken | Next Steps |
|---|---|---|---|
| 11/05/2026 | PUCT | Approved | |
| 09/15/2026 | BOARD | Recommended for Approval | PUCT for consideration |
| 08/26/2026 | TAC | Recommended for Approval | Board for consideration |
| 08/12/2026 | PRS | Recommended for Approval | TAC for consideration |
| 07/15/2026 | PRS | Deferred/Tabled | PRS for consideration |
| 06/10/2026 | PRS | Recommended for Approval | PRS for consideration |
| 05/14/2025 | PRS | Deferred/Tabled | PRS for consideration |
| 04/09/2025 | PRS | Deferred/Tabled | PRS for consideration |
| 03/12/2025 | PRS | Recommended for Approval | PRS for Impact Analysis consideration |
| 01/11/2024 | PRS | Deferred/Tabled | PRS for consideration |
Voting Record
| Date | Gov Body | Motion | Result |
|---|---|---|---|
| 11/05/2026 | PUCT | To approve NPRR1214 and accompanying ERCOT Market Impact Statement as presented in Project No. 54445, Review of Protocols Adopted by the Independent Organization | Passed |
| 09/15/2026 | BOARD | To recommend approval of NPRR1214 as recommended by TAC in the 8/26/26 TAC Report | Passed |
| 08/26/2026 | TAC | To recommend approval of NPRR1214 as recommended by PRS in the 8/12/26 PRS Report | Passed |
| 08/12/2026 | PRS | To endorse and forward to TAC the 7/15/26 PRS Report and 8/11/26 Revised Impact Analysis for NPRR1214 with a recommended priority of 2027 and rank of 4940 | Passed |
| 07/15/2026 | PRS | To table NPRR1214 | Passed |
| 06/10/2026 | PRS | To endorse the 5/14/25 PRS Report as amended by the 6/5/26 ERCOT comments for NPRR1214; and to bring the Revised Impact Analysis back to PRS | Passed |
| 05/14/2025 | PRS | To table NPRR1214 | Passed |
| 04/09/2025 | PRS | To table NPRR1214 | Passed |
| 03/12/2025 | PRS | To recommend approval of NPRR1214 as amended by the 1/28/25 ERCOT comments | Passed |
| 01/11/2024 | PRS | To table NPRR1214 and refer the issue to WMS | Passed |
Background
| Status: | Approved |
|---|---|
| Date Posted: | Dec 7, 2023 |
| Sponsor: | Joint Sponsors |
| Urgent: | No |
| Sections: | 2.1, 3.2.5, 3.5.2.1, 3.5.2.2, 3.5.2.3, 3.5.2.4, 3.5.2.5, 3.5.2.6, 3.5.2.7, 4.4.11, 5.5.2, 5.7.1.3, 5.7.1.4, 6.3.2, 6.5.7.3, 6.5.7.3.1, 6.5.9.2, 6.6.1.1, 6.6.1.2, 6.6.1.6, 6.6.1.7 (delete), 6.6.3.1, 6.6.3.6, 6.6.3.8, 6.6.6.3, 6.6.6.10, 6.7.5, 6.7.6, 6.9 (new), 6.9.1 (new), 6.9.2 (new), and 9.5.3 |
| Description: | This Nodal Protocol Revision Request (NPRR) revises the Real-Time On-Line Reliability Deployment Price Adder (RTRDPA) to: send appropriate locational price signals to avoid counterproductive Load and Resource responses to RTRDPA price signals under Real-Time Co-optimization (RTC); limit Resource payment to the actual “indifference payment” (consistent with its definition), thereby reducing associated uplift by eliminating the future need for RTRDPA payments to Resources that exacerbate constraints and eliminating payments to available capacity not requiring an indifference payment; eliminate any future need for the Ancillary Service Imbalance Payments or Charges (ASIP/C) type of indifference payment associated with RTRDPA, thereby reducing the risk associated with providing Ancillary Services; provide Resources an indifference payment under RTC to eliminate the potentially large incentive to ignore Base Point instructions that would likely cause serious reliability issues; and provide a stronger locational price signal around Resources committed by the Reliability Unit Commitment (RUC) process or other reliability actions for congestion, thereby reducing RUC Make-Whole Payment-related charges and uplifts and appropriately compensating impacted Qualified Scheduling Entities (QSEs). |
| Reason: | Strategic Plan Objective 2 |
Key Documents
Dec 7, 2023 - docx - 131.5 KB
Jan 16, 2024 - xls - 140.5 KB
Jan 16, 2024 - docx - 138.1 KB
Feb 8, 2024 - xls - 141.5 KB
Feb 8, 2024 - doc - 41 KB
Aug 9, 2024 - docx - 27.2 KB
Nov 4, 2024 - docx - 136.8 KB
Jan 28, 2025 - docx - 402.4 KB
Mar 6, 2025 - xls - 142 KB
Mar 6, 2025 - doc - 40.5 KB
Mar 17, 2025 - xls - 140.5 KB
Mar 17, 2025 - docx - 403 KB
Mar 31, 2025 - docx - 31.1 KB
Apr 11, 2025 - xls - 156.5 KB
Apr 11, 2025 - docx - 403.1 KB
May 13, 2025 - docx - 31.3 KB
May 17, 2025 - xls - 141 KB
May 17, 2025 - docx - 405.6 KB
May 28, 2026 - docx - 86.9 KB
May 29, 2026 - docx - 488 KB
Jun 5, 2026 - docx - 501 KB
Jun 10, 2026 - xls - 140 KB
Jun 10, 2026 - docx - 474.3 KB
Jun 22, 2026 - docx - 102 KB
Jul 9, 2026 - docx - 31.3 KB
Jul 15, 2026 - xls - 140 KB
Jul 15, 2026 - docx - 469 KB
Aug 11, 2026 - docx - 31.5 KB
Aug 13, 2026 - xls - 140 KB
Aug 13, 2026 - docx - 467.9 KB
Aug 27, 2026 - xls - 141 KB
Aug 27, 2026 - docx - 473.9 KB
Sep 15, 2026 - docx - 473 KB
Nov 9, 2026 - docx - 473.8 KB