| PGRR003 |
New Planning Guide Section 9A, SSWG Procedure Manual |
This Planning Guide Revision Request (PGRR) adds new Section 9 Appendices, Attachment A, Steady State Working Group (SSWG) Procedure Manual to the Planning Guide. |
11/23/2010 |
Planning Working Group (PLWG) |
No |
Section 9, Appendix A (new) |
Withdrawn |
|
| PGRR028 |
Evaluation of Compliance with Reactive Requirements |
This Planning Guide Revision Request (PGRR) defines ERCOT’s process for evaluation proposed Generation Resources’ ability to provide reactive power. Protocol Section 3.15, Voltage Support, defines reactive capability requirements for Generation Resources. Paragraph (3) of Protocol Section 16.5, Registration of a Resource Entity requires ERCOT to opine upon the capability of the proposed Generation Resource’s ability to meet these requirements. |
02/12/2013 |
ERCOT |
No |
5.6.1 (new) |
Withdrawn |
|
| PGRR034 |
Asynchronous Tie Interconnection Process |
This Planning Guide Revision Request (PGRR) incorporates the ERCOT white paper describing the Asynchronous Tie Interconnection Process into the Planning Guides. |
10/08/2013 |
Pattern Energy |
No |
2.2, 5, 5.1, 5.1.1, 5.1.2, 5.2.1, 5.3, 5.3.1, 5.3.2, 5.4, 5.4.1, 5.4.2, 5.4.2.1, 5.4.2.2, 5.4.3, 5.4.4, 5.4.5, 5.4.5.1, 5.4.6, 5.4.7, 5.4.8, 5.4.9, 5.4.10, 5.5, 5.5.1, 5.5.2, 5.5.3, 5.5.4, 5.6, 5.7, 5.7.1, 5.7.2, 5.7.3, 5.7.4, 5.7.5, 5.8, 5.8.1, 5.8.2, 5.3 (new), 5.3.1 (new), 5.3.2 (new), 5.3.3 (new), 5.3.3.1 (new), 5.3.3.2 (new), 5.3.4 (new), 5.3.4.1 (new), 5.3.5 (new), 5.3.5.1 (new), 5.3.5.2 (new), 5.3.6 (new), 5.3.7 (new), 5.3.8 (new), 5.3.8.1 (new), 5.3.9 (new), 5.3.10 (new), 5.3.11 (new), 5.3.12 (new), 5.3.13 (new), 5.3.14 (new), 5.3.15 (new), 5.3.15.1 (new), 5.3.16 (new), 5.3.17 (new), 5.3.17.1 (new), 5.3.18 (new), 5.3.19 (new), 5.3.20 (new), 6.11 (new), |
Withdrawn |
|
| PGRR035 |
DC Tie Interconnection Process |
This Planning Guide Revision Request (PGRR) incorporates the ERCOT white paper describing the Asynchronous Tie Interconnection Process into the Planning Guides; renames the "Tie" to be "DC Tie"; and reflects the current definition of DC Tie in the Protocols. This PGRR also replaces PGRR034, Asynchronous Tie Interconnection Process, which was withdrawn on 10/28/13. |
11/04/2013 |
John Moore on behalf of Pattern Energy |
No |
2.2, 6.11 (new), 7 (new), 7.1 (new), 7.1.1 (new), 7.1.2 (new), 7.2 (new), 7.2.1 (new), 7.2.2 (new), 7.3 (new), 7.3.1 (new), 7.3.2 (new), 7.4 (new), 7.4.1, (new), 7.4.2 (new), 7.4.3 (new), 7.4.3.1 (new), 7.4.3.2 (new), 7.4.3.3 (new), 7.4.3.4 (new), 7.4.3.5 (new), 7.5 (new), 7.6 (new), 7.7 (new), 7.8 (new), 7.9 (new), 7.10 (new), 7.11 (new), 7.12 (new), 7.13 (new), 7.14 new), 7.14.1 (new), 7.14.2 (new), 7.15 (new) |
Withdrawn |
|
| PGRR097 |
Related to NPRR1098, Direct Current Tie (DC Tie) Reactive Power Capability Requirements |
This Planning Guide Revision Request (PGRR) clarifies the responsibilities of Direct Current Tie Operators (DCTOs) relative to the develop of dynamics models and aligns the Planning Guide with the revisions proposed in NPRR1098. |
09/29/2021 |
ERCOT |
No |
6.2 and 6.2.3 |
Withdrawn |
|
| PGRR105 |
Deliverability Criteria for DC Tie Imports |
This Planning Guide Revision Request (PGRR) adds Direct Current Tie (DC Tie) Resources to the list of Resources for which the minimum deliverability condition applies. |
04/17/2023 |
Rainbow Energy Marketing Corporation |
No |
4.1.1.1, 4.1.1.7 |
Withdrawn |
|
| PGRR111 |
Related to NPRR1191, Registration, Interconnection, and Operation of Customers with Large Loads; Information Required of Customers with Loads 25 MW or Greater |
This Planning Guide Revision Request (PGRR) creates a new process for studying the reliability impacts of all Large Loads (those 75MW or more) that will be interconnected within 24 months. As with the Full Interconnection Study (FIS) required for proposed Generation Resources, this PGRR requires a Large Load Interconnection Study (LLIS) for each new Large Load meeting applicability requirements that is proposed to interconnect to the ERCOT System. Like the FIS, the LLIS will consist of a similar suite of studies conducted by one or more affected Transmission Service Providers (TSP). This PGRR describes these studies in detail and establishes timelines for the review of these studies and the completion of other steps in the interconnection process. This PGRR requires a Customer proposing to interconnect such a Load—referred to as a “Large Load Interconnecting Entity”—to initiate such a request through ERCOT’s Resource Integration and Ongoing Operations (RIOO) system, which will leverage the efficiency of this existing tool to enable ERCOT and affected TSPs to submit, review, and confirm completion of the studies that are needed. This PGRR also requires some Large Loads to be evaluated as part of the existing quarterly stability assessment. This PGRR also adds additional Reliability Performance Criteria for the inclusion of Large Loads in planning studies. |
08/01/2023 |
ERCOT |
No |
2.1, 4.1.1.2, 5.2.10 (new), 5.3.5, 6.1, 6.6 (new), 6.6.1 (new), 6.6.2 (new), 6.6.3 (new), 6.6.4 (new), 7.1, 9 (new), 9.1 (new), 9.2 (new), 9.2.1 (new), 9.2.2 (new), 9.2.3 (new), 9.2.4 (new), 9.3 (new), 9.3.1 (new), 9.3.2 (new), 9.3.3 (new), 9.3.4 (new), 9.3.4.1 (new), 9.3.4.2 (new), 9.3.4.3 (new), 9.4 (new), 9.5 (new), 9.5.1 (new), 9.5.2 (new), 9.5.3 (new), 9.6 (new) |
Withdrawn |
|
| PGRR126 |
Related to NPRR1284, Guaranteed Reliability Load Process |
This Planning Guide Revision Request (PGRR) details how Guaranteed Reliability Loads (GRLs), as defined in the related NPRR1284, shall be incorporated into ERCOT planning studies. |
05/12/2025 |
Cholla Petroleum |
No |
4.1.1.1, 4.1.1.9 (new), and 7.1 |
Withdrawn |
|
| PGRR130 |
Related to NPRR1295, GTC Exit Solutions |
This Planning Guide Revision Request (PGRR) details how Generic Transmission Constraint (GTC) exit solutions, as defined in the related NPRR1295, shall be incorporated into ERCOT planning studies. |
08/19/2025 |
Joint Sponsors |
No |
3.1.3.3 (new) |
Withdrawn |
|
| PGRR134 |
Interconnection Studies Reform for Dispatchable Loads |
This PGRR allows Interconnecting Large Load Entities (ILLEs) to submit an NPRR1188-compliant Controllable Load Resources (CLR) election to the reviewing Transmission Service Provider (TSP). TSPs treat the election as a CLR Election Study input, model the site as an NPRR1188-compliant CLR, and may authorize earlier energization when constraints can be mitigated by dispatch down to the CLR Low Power Consumption (LPC), which may equal zero for the CLR. All Load would still be studied for delivery of their full capacity with timelines for firm network service outlined in the Load Commissioning Plan (LCP). Additionally, this PGRR directs that each proposed Large Load that elects to be studied as a CLR will be studied using the LPC and Maximum Power Consumption (MPC) provided as part of project information described in Section 9.2.2, Submission of Large Load Project Information and Initiation of the Large Load Interconnection Study (LLIS). It further directs that for the purposes of the Large Load Interconnection Study Methodology, CLRs will be studied assuming registration and qualification under NPRR1188 or any successor provision. Finally, this PGRR prohibits a CLR from using this program if it would impair a previously submitted Large Load’s requested energization date or energization capacity and that ERCOT may specify Interconnection Reliability Operating Limits (IROLs) or other reliability related transmission limits which cannot be resolved with CLR dispatch. |
11/01/2025 |
Luminary Strategies |
No |
2.1, 4.1.1.1, 4.1.1.7, and 6.1 |
Withdrawn |
|
| PGRR135 |
Large Load Interconnection Queue Process Revision |
This Planning Guide Revision Request (PGRR) changes the criteria of the Large Load Interconnection Study (LLIS) process to use demonstrated financial commitment in place of signed Load interconnection as a requirement for advancement. |
11/04/2025 |
Cholla Petroleum |
Pending |
9.3.4.1 |
Withdrawn |
|
| PGRR136 |
Large Load Interconnection Study Scope Documentation |
This Planning Guide Revision Request (PGRR) implements targeted revisions to Section 9.3.2 to strengthen Large Load Interconnection Study (LLIS) scoping requirements and improve transparency across ERCOT, Transmission Service Providers (TSPs), and Interconnecting Large Load Entities (ILLEs) by enhancing documentation. |
11/25/2025 |
Schaper Energy Consulting |
No |
9.3.2 |
Withdrawn |
|
| PGRR138 |
Large Load Interconnection Study Review and Approval Process |
This Planning Guide Revision Request (PGRR) modifies Section 9.4 to improve the transparency and efficiency of requirements related to the LLIS report and follow-up. |
12/01/2025 |
Schaper Energy Consulting |
No |
9.4 |
Withdrawn |
|
| PGRR141 |
Large Load Interconnection Study Reform for Substantiated Load |
This Planning Guide Revision Request (PGRR) enables more efficient Large Load studies, approvals, and subsequent transmission planning by allowing a Regional Planning Group (RPG) review to be used in place of a separate Large Load Interconnection Study (LLIS) when evaluating a substantiated Large Load interconnection. |
12/31/2025 |
Joint Sponsors |
No |
9.3.1 |
Withdrawn |
|