Notice_PRR_SCR@lists.ercot.com,Notice_Settlements@lists.ercot.com,NOTICE_GENERAL@LISTS.ERCOT.COM,Notice_Operations@lists.ercot.com,Notice_Release_Retail@lists.ercot.com,Notice_Release_Wholesale@lists.ercot.com
5/13/22, 9:36 AM
M-A042222-02 Implementation Details of NPRR1093, NPRR1101, OBDRR032, OBDRR033, and OBDRR035
NOTICE DATE: May 13, 2022
NOTICE TYPE: M-A042222-02 NPRR
SHORT DESCRIPTION: Implementation Details of NPRR1093, NPRR1101, OBDRR032, OBDRR033, and OBDRR035
INTENDED AUDIENCE: All Market Participants
DAYS AFFECTED: May 27, 2022
LONG DESCRIPTION: On May 27, 2022, Protocol and Other Binding Document language associated with the following Revision Requests will be implemented:
- Nodal Protocol Revision Request (NPRR) 1093, Load Resource Participation in Non-Spinning Reserve;
- NPRR1101, Create Non-Spin Deployment Groups made up of Generation Resources Providing Off-Line Non-Spinning Reserve and Load Resources that are Not Controllable Load Resources Providing Non-Spinning Reserve;
- Other Binding Document Revision Request (OBDRR) 032, Non-Spin Changes Related to NPRR1093;
- OBDRR033, ORDC Changes Related to NPRR1093; and
- OBDRR035, Non-Spin Changes Related to NPRR1101
The combination of the above Revision Requests allow for Non-Spinning Reserve (Non-Spin) provision from Load Resources that are not Controllable Load Resources and defines how Resources providing Non-Spin are grouped and deployed.
Technical specifications of the changes to ERCOT interfaces as a result of this effort were shared at the February 10, 2022 Technology Working Group meeting. ERCOT also hosted an April 25, 2022 workshop to provide additional details on this effort.
ERCOT Market Operations Test Environment (MOTE) is available for Market Participants to voluntarily test submission functions related to NPRR1093, which began May 5, 2022.
NPRR1093 introduces the following changes to the Settlement System:
- Protocol Section 6.7.5, Real-Time Ancillary Service Imbalance Payment or Charge – Updates Online Imbalance and Offline Imbalance calculations to account for Load Resources that are not Controllable Load Resources participating in Non-Spin Reserve.
New Settlement Billing Determinants:
Billing Determinant |
Short Description |
Extract |
Extract Table |
RTNCLRNSRESPR |
Real-Time Non-Controllable Load Resource Non-Spin Responsibility for the Resource |
SID & RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
RTNCLRNSRESP |
Real-Time Non-Controllable Load Resource Non-Spin Responsibility for the QSE |
RTM CODE |
RTMOUTPUTHEADER RTMOUTPUTINTERVAL |
RTNCLRNSR |
Real-Time Non-Spin Schedule for the Non-Controllable Load Resource |
SID & RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
RTNCLRNS |
Real-Time Non-Spin Schedule for the Non-Controllable Load Resources for the QSE |
RTM CODE |
RTMOUTPUTHEADER RTMOUTPUTINTERVAL |
RTNCLRNSCAP |
Real-Time Capacity from Non-Controllable Load Resources Carrying Non-Spin for the QSE |
RTM CODE |
RTMOUTPUTHEADER RTMOUTPUTINTERVAL |
Additionally, there will be several reporting changes introduced with the implementation of NPRR1093. Please note that changes to disclosure reports will occur post implementation and align to the applicable operating days affected.
The following new Certified reports will need to be added to the EMIL and MIS:
1) Monthly Non-Spin NCLR Performance Report | NP8-385-ER | Report Type ID 22069
2) Group Assignments for NCLRs and Off-Line Generation Resources Participating in NSRS | NP6-577-CD | Report Type ID 21939
The following two reports will have a column added for ‘RTNCLRNSCAP’:
1) Real-Time ORDC and Reliability Deployment Price Adders and Reserves by SCED Interval |NP6-323-CD| Report Type ID 13221
2) Historical Real Time ORDC and Reliability Deployment Price Adders and Reserves |NP6-792-ER| Report Type ID 13231
The following reports will be modified for the NSPIN Column to be split out to account for new subtype of NSPNM:
1) 60D SCED Disclosure Report | NP3-965-ER | Report Type ID 13052
Output file: Output file: 60-Day QSE-Specific Self-Arranged AS in SCED
2) 60D DAM Disclosure Report | NP3-966-ER | Report Type ID 13051
Output file: Output file: 60-Day QSE-Specific Self-Arranged AS in DAM
Lastly, a new output file will be added within the zipfile for 2-Day Ancillary Services Disclosure |NP3-911-ER | Report Type ID 13057
AS ‘2d_Self_Arranged_AS_NSPNM’ due to new NSPNM subtype
ACTION REQUIRED: Impacted Market Participants should implement changes to their shadow Settlement systems to incorporate the revisions made by NPRR1093, NPRR1101, OBDRR032, OBDRR033, and OBDRR035.
ADDITIONAL INFORMATION: Pursuant to Nodal Protocol Section 21.6, Nodal Protocol Revision Implementation, ERCOT is required to provide notice as soon as practicable, but no later than ten days prior to implementation.
NPRR1093, NPRR1101, OBDRR032, OBDRR033, OBDRR035 and their associated documents can be found on the ERCOT website.
Additional Settlement details can be found in the Settlements Charge Matrix located on the Settlements page on ERCOT.com.
Resource Entities and Qualified Scheduling Entities (QSEs) representing Load Resources that are interested in providing Non-Spin pursuant to the changes in this effort are encouraged to review the meeting materials from the April 25, 2022 workshop.
CONTACT: If you have any questions, please contact your ERCOT Account Manager. You may also call the general ERCOT Client Services phone number at (512) 248-3900 or contact ERCOT Client Services via email at ClientServices@ercot.com.
If you are receiving email from a public ERCOT distribution list that you no longer wish to receive, please follow this link in order to unsubscribe from this list: http://lists.ercot.com.
dg