M-A052424-01 Implementation Details of NPRR1139 and NPRR1149 (Settlement-Related)
NOTICE DATE: May 24, 2024
NOTICE TYPE: M-A052424-01 NPRR
SHORT DESCRIPTION: Implementation Details of NPRR1139 and NPRR1149 (Settlement-Related)
INTENDED AUDIENCE: All Market Participants
DAYS AFFECTED: June 27, 2024
LONG DESCRIPTION: On June 27, 2024, Protocol language associated with Nodal Protocol Revision Request (NPRR) 1139, Adjustments to Capacity Shortfall Ratio Share for IRRs, and NPRR1149, Implementation of Systematic Ancillary Service Failed Quantity Charges, will be implemented.
NPRR1139 introduces the following Settlement-related changes to the Protocols:
- 5.7.4.1(1), RUC Capacity-Short Charge – Minor revision to change "HSL" to "RUCHSL" in a formula variable to match the data value in the Settlement extracts.
- 5.7.4.1.1(1), Capacity Shortfall Ratio Share – Revision to the calculation of available capacity (HASLSNAP) for an IRR to be the lesser of the HSL value as reflected in the COP and the Wind-powered Generation Resource Production Potential (WGRPP) for a Wind-powered Generation Resource (WGR), or the PhotoVoltaic Generation Resource Production Potential (PVGRPP) for a PhotoVoltaic Generation Resource (PVGR), at the time of the RUC execution.
NPRR1149 introduces the following Settlement-related changes to the Protocols:
- 6.7.3, Charges for a Failure to Provide – This section details the new methodology for calculating charges related to a Failure to Provide. After the completion of the Operating Hour, comparisons will be made between the Ancillary Service (AS) Supply Responsibility and the Real-Time telemetry. The calculation now includes averaging the sum of the Real-Time On-Line Reliability Deployment Price and the Real-Time Reserve Price for On-Line Reserves. This average will be used in determining the maximum price. For each Qualified Scheduling Entity (QSE), the maximum price will be applied to the total of the AS Failure Quantity and the Telemetered AS Failure Quantity.
New Settlement Billing Determinants:
|
Billing Determinant |
Short Description |
Extract |
Extract Table |
|
AVGRTASIP |
Average Real-Time Ancillary Service Imbalance Price |
RTM MODE |
RTMOUTPUTHEADER RTMOUTPUTINTERVAL |
|
TRUFQ |
Telemetered Reg-Up Failure Quantity per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TRDFQ |
Telemetered Reg-Down Failure Quantity per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TRRFQ |
Telemetered Responsive Reserve Failure Quantity per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TNSFQ |
Telemetered Non-Spin Failure Quantity per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TECRFQ |
Telemetered ERCOT Contingency Reserve Service Failure Quantity per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RUTRSQ |
Reg-Up Trade Sale per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RDTRSQ |
Reg-Down Trade Sale per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RRTRSQ |
Responsive Reserve Trade Sale per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
NSTRSQ |
Non-Spinning Reserve Trade Sale per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
ECRTRSQ |
ERCOT Contingency Reserve Service Trade Sale |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RUCRUQ |
RUC-committed for Reg-Up per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RUCRDQ
|
RUC-committed for Reg-Down per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RUCRRQ |
RUC-committed for Responsive Reserve per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RUCNSQ |
RUC-committed for Non-Spin Reserve per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RUCECRQ |
RUC-committed for ERCOT Contingency Reserve Service per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RUTRPQ |
Reg-Up Trade Purchases per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RDTRPQ |
Reg-Down Trade Purchases per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
RRTRPQ |
Responsive Reserve Trade Purchases per QSE
|
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
NSTRPQ |
Non-Spin Reserve Trade Purchases per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
ECRTRPQ |
ERCOT Contingency Reserve Service Trade Purchases per QSE |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TELRUR
|
Telemetered Reg-Up Responsibility for the Resource |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TELRDR |
Telemetered Reg-Down Responsibility for the Resource |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TELRRSRC
|
Telemetered Responsive Reserve Responsibility for the Resource as Calculated |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TELNSRC
|
Telemetered Non-Spin Reserve Responsibility for the Resource as Calculated |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
|
TELECRRC |
Telemetered ERCOT Contingency Reserve Service Responsibility for the Resource as Calculated |
RTM CODE |
MKTINPUTHEADER MKTINPUTINTERVAL |
ACTION REQUIRED: Impacted Market Participants should implement changes to their shadow Settlement systems to incorporate the Protocol revisions made by NPRR1139 and NPRR1149.
ADDITIONAL INFORMATION: Pursuant to Nodal Protocol Section 21.6, Nodal Protocol Revision Implementation, ERCOT is required to provide notice as soon as practicable, but no later than ten days prior to implementation.
NPRR1139 and NPRR1149 and their associated documents can be found on the ERCOT website.