M-B050523-01 Implementation Details of NPRR863 and NPRR1085


NOTICE DATE: May 5, 2023

NOTICE TYPE: M-B050523-01 NPRR

SHORT DESCRIPTION: Implementation Details of NPRR863 and NPRR1085

INTENDED AUDIENCE: All Market Participants

DAYS AFFECTED: June 6-8, 2023

LONG DESCRIPTION: On June 6 - 8, 2023, Protocol language associated with Nodal Protocol Revision Request (NPRR) 863 Creation of ERCOT Contingency Reserve Service (ECRS) and Revisions to Responsive Reserve, and NPRR1085, Ensuring Continuous Validity of Physical Responsive Capability (PRC) and Dispatch through Timely Changes to Resource Telemetry and Current Operating Plans (COPs).

NPRR863 introduces the following changes to the following Protocol Sections:

  • 4.6.2.3.1, Day-Ahead Make-Whole Payment – Revision to Day-Ahead Make-Whole Revenue calculation for each DAM-Committed Generation Resource (DAASREV) to include ECRS
  • 4.6.4.1.5, ERCOT Contingency Reserve Service Payment – Creation of new Charge Type for Payments for Ancillary Services Procured in the Day-Ahead Market (DAM) for ECRS
  • 4.6.4.2.5, ERCOT Contingency Reserve Charge Creation of new Charge Type for Charges for ECRS procured in the DAM
  • 6.6.5.1.1, General Generation Resource and Controllable Load Resource Base Point Deviation Charge Creation of a new system wide exemption for ECRS
  • 6.7.1, Payments for Ancillary Service Capacity Sold in a Supplemental Ancillary Services Market (SASM) or Reconfiguration Supplemental Ancillary Services Market (RSASM) – Creation of new Charge Type for ECRS
  • 6.7.2, Payments for Ancillary Service Capacity Assigned in Real-Time Operations – Creation of new payment for ECRS
  • 6.7.2.1, Charges for Infeasible Ancillary Service Capacity Due to Transmission Constraints – Creation of new Charge Type for ECRS
  • 6.7.3, Charges for Ancillary Service Capacity Replaced Due to Failure to Provide – Creation of new Charge Type for ECRS
  • 6.7.4, Adjustments to Cost Allocations for Ancillary Services Procurement – Creation of new Charge Type for ECRS
  • 6.7.5, Real-Time Ancillary Service Imbalance Payment or Charge – Revision to the calculations of Real-Time Capacity for Non-Controllable Load Resources carrying ERCOT Contingency Reserve or Responsive Reserve for the Qualified Scheduling Entity (QSE) (RTNCLRCAP) and Real-Time Ancillary Service Supply Responsibility for Reliability Must-Run (RMR) Units represented by the QSE (RTRMRRESP) to include ECRS
  • 6.7.7, Adjustments to Net Cost Allocations for Real-Time Ancillary Services – Creation of new charge for ECRS

 

NPRR1085 introduces the following changes to the following Protocol Sections:

  • 6.7.5, Real-Time Ancillary Service Imbalance Payment or Charge – Revision to Real-Time On-Line Reserve Capacity for the QSE (RTOLCAP) to exclude the capacity from Generation Resources with a telemetered status of ONHOLD

New Settlement Billing Determinants:

Billing Determinant

Short Description

Extract

Extract Table

MCPCECR

Market Clearing Price for Capacity for ERCOT Contingency Reserve Service by market

DAM MODE

MKTINPUTHEADER

MKTINPUTINTERVAL

PCECRR

Procured Capacity for ERCOT Contingency Reserve Service from Resource per Resource per QSE by market

DAM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

PCECR

Procured Capacity for ERCOT Contingency Reserve Service per QSE in DAM

DAM CODE

DAMOUTPUTHEADER

DAMOUTPUTINTERVAL

PCECRAMT

Procured Capacity for ERCOT Contingency Reserve Service Amount per QSE in DAM

DAM CODE

DAMOUTPUTHEADER

DAMOUTPUTINTERVAL

PCECRAMTTOT

Procured Capacity for ERCOT Contingency Reserve Amount Total in DAM

DAM MODE

DAMOUTPUTHEADER

DAMOUTPUTINTERVAL

DAECRO

Day-Ahead ERCOT Contingency Reserve Obligation per QSE

DAM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

DASAECRQ

Day-Ahead Self-Arranged ERCOT Contingency Reserve Quantity per QSE

DAM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

DAECRQ

Day-Ahead ERCOT Contingency Reserve Quantity per QSE

DAM CODE

DAMOUTPUTHEADER

DAMOUTPUTINTERVAL

DAECRQTOT

Day-Ahead ERCOT Contingency Reserve Quantity Total

DAM MODE

DAMOUTPUTHEADER

DAMOUTPUTINTERVAL

DAECRPR

Day-Ahead ERCOT Contingency Reserve Price

DAM MODE

DAMOUTPUTHEADER

DAMOUTPUTINTERVAL

DAECRAMT

Day-Ahead ERCOT Contingency Reserve Amount per QSE

DAM CODE

DAMOUTPUTHEADER

DAMOUTPUTINTERVAL

RTPCECR

Procured Capacity for ERCOT Contingency Reserve Service by QSE by market

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

RTPCECRAMT

Procured Capacity for ERCOT Contingency Reserve Service Amount by QSE by market

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRINFQ

ERCOT Contingency Reserve Service Infeasibility Quantity per QSE

RTM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

ECRINFQAMT

ERCOT Contingency Reserve Service Infeasible Quantity Amount per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

RECRFQ

Reconfiguration ERCOT Contingency Reserve Service Failure Quantity per QSE

RTM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

ECRFQ

ERCOT Contingency Reserve Service Failure Quantity per QSE

RTM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

RECRFQAMT

Reconfiguration ERCOT Contingency Reserve Service Failure Quantity Amount per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRFQAMT

ERCOT Contingency Reserve Service Failure Quantity Amount per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRFQAMTQSETOT

ERCOT Contingency Reserve Service Failure Quantity Amount per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRINFQAMTTOT

ERCOT Contingency Reserve Service Infeasible Quantity Amount Total

RTM MODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

RTPCECRAMTQSETOT

Procured Capacity for ERCOT Contingency Reserve Service Amount Total per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRFQAMTTOT

ERCOT Contingency Reserve Service Failure Quantity Amount Total

RTM MODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

RTPCECRAMTTOT

Procured Capacity for ERCOT Contingency Reserve Service Amount Total by market

RTM MODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRCOSTTOT

ERCOT Contingency Reserve Service Cost Total

RTM MODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

SAECRQ

Total Self-Arranged ERCOT Contingency Reserve Service Quantity per QSE for all markets

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

RTSAECRQ

Self-Arranged ERCOT Contingency Reserve Service Quantity per QSE for all SASMs

RTM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

ECRO

ERCOT Contingency Reserve Service Obligation per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRQ

ERCOT Contingency Reserve Service Quantity per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRQTOT

ERCOT Contingency Reserve Service Cost Total

RTM MODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRPR

ERCOT Contingency Reserve Service Price

RTM MODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

ECRCOST

ERCOT Contingency Reserve Service Cost per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

RTECRAMT

Real-Time ERCOT Contingency Reserve Service Amount Per QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

HECRADJ

Ancillary Service Resource Responsibility Capacity for ERCOT Contingency Reserve Service at Adjustment Period

RTM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

RTNCLRECRSR

Real-Time Non-Controllable Load Resource ERCOT Contingency Reserve

RTM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

RTNCLRECRS

Real-Time Non-Controllable Load Resource ERCOT Contingency Reserve for the QSE

RTM CODE

RTMOUTPUTHEADER

RTMOUTPUTINTERVAL

STATUSONHOLD

Telemetered Status On-Hold Flag

RTM CODE

MKTINPUTHEADER

MKTINPUTINTERVAL

ECRSFLAG

ERCOT Contingency Reserve Service Flag

RTM MODE

MKTINPUTHEADER

MKTINPUTINTERVAL

 

ACTION REQUIRED:  Impacted Market Participants should implement changes to their shadow Settlement systems to incorporate the Protocol revisions made by NPRR863 and NPRR1085.

ADDITIONAL INFORMATION: Pursuant to Nodal Protocol Section 21.6, Nodal Protocol Revision Implementation, ERCOT is required to provide notice as soon as practicable, but no later than ten days prior to implementation.

NPRR863 and NPRR1085  and their associated documents can be found on the ERCOT website.

CONTACT: If you have any questions, please contact your ERCOT Account Manager. You may also call the general ERCOT Client Services phone number at (512) 248-3900 or contact ERCOT Client Services via email at ClientServices@ercot.com.

If you are receiving email from a public ERCOT distribution list that you no longer wish to receive, please follow this link in order to unsubscribe from this list: http://lists.ercot.com.

 

mm


Attachments: