Notice_PRR_SCR@lists.ercot.com,Notice_Operations@lists.ercot.com

12/3/25, 12:15 PM

M-A110525-03 RTC+B: Implementation of credit provisions of NPRR1013


NOTICE DATE: December 3, 2025

NOTICE TYPE: M-A110525-03 NPRR

SHORT DESCRIPTION: RTC+B: Implementation of credit provisions of NPRR1013

INTENDED AUDIENCE: All Market Participants

DAYS AFFECTED: December 5 and 6, 2025

LONG DESCRIPTION: On December 5, 2025, Real-Time Co-optimization Plus Batteries (RTC+B) project changes related to credit provisions of Nodal Protocol Revision Request (NPRR) 1013, RTC - NP 1, 2, 16, and 25: Overview, Definitions and Acronyms, Registration and Qualification of Market Participants, and Market Suspension and Restart, will be implemented.

Report changes on December 5, 2025:

Beginning on December 5, 2025, the afternoon version of the following two reports will have changes implemented:

  1. Estimated Aggregate Liability (EAL) Detail Report (EMIL ID: NP16-669-SG, Report Type ID: 11179) (ERCOT Protocol Section 16.11.4.7, Credit Monitoring and Management Reports) will include the following new columns in the "RTLCNS Details for all QSEs of the Counter-Party Section" and "RTLF Details for all QSEs of the Counter-Party section":
  • Real-Time Ancillary Service Volume (MWh)
  • Real-Time Ancillary Service Amount ($)

  1. Minimum Current Exposure (MCE) Summary Report (EMIL ID: NP16-678-SG, Report Type ID: 13092) (ERCOT Protocol Section 16.11.4.7, Credit Monitoring and Management Reports) will include the following new columns:
  • Extrapolated volume of Day- Ahead Ancillary Service- Only Offers Cleared
    (MWh)
  • Extrapolated amount of Day- Ahead Real- Time Net Ancillary Service- Only Offers Cleared Exposure ($)

Calculation changes on December 6, 2025:

Beginning on December 6, 2025:

  1. The Minimum Current Exposure (MCE) component of Total Potential Exposure (TPE) calculation (ERCOT Protocol Section 16.11.4.1, Determination of Total Potential Exposure for a Counter-Party) will be updated to include Real-Time Co-optimization (RTC) Ancillary Service virtual offers activity to capture price risk between Day -Ahead Market (DAM) Market Clearing Price for Capacity (MCPC) and Real-Time Market (RTM) Market Clearing Price for Capacity (MCPC).

  1. The Unbilled Day-Ahead Amounts (UDAA) component of the EAL calculation (ERCOT Protocol Section 16.11.4.3.1, Day-Ahead Liability Estimate) will be updated to include RTC Ancillary Service virtual offers activity.
  • Currently: Ancillary Service activity is captured in Ancillary Services payments and charges
  • With RTC: Ancillary Service virtual offers are captured in Ancillary Services payments and charges

  1. The Real-Time Liability Completed and Not Settled (RTLCNS) and Real-Time Liability Forward (RTLF) components of the EAL calculation (ERCOT Protocols Section 16.11.4.3.2, Real-Time Liability Estimate) will be updated to include RTC Ancillary Services activity to capture Ancillary Service payments and charges in RTLCNS and capture Ancillary Services payments and charges in RTLF (150% of Ancillary Services payments and charges).

Operating Day December 5, 2025 data:

For report date December 5, 2025, Operating Day (OD) December 5, 2025 data will not be included in the following calculations:

  • UDAA component of EAL under ERCOT Protocol Section 16.11.4.3.1, Day-Ahead Liability Estimate;
  • Portfolio- Weighted Adder (PWA ci100, m) component of Future Credit Exposure for Point-to-Point (PTP) Obligations (FCEOBL) under paragraph (2) of ERCOT Protocol Section 16.11.4.5, Determination of the Counter-Party Future Credit Exposure; and
  • Path- Specific DAM- Based Adder (A ci99, ctou, (j, k)) component of Future Credit Exposure for PTP Options (FCEOPT) under paragraph (3) of ERCOT Protocol Section 16.11.4.5, Determination of the Counter-Party Future Credit Exposure.

Please monitor your Credit Monitoring and Management Reports and manage collateral accordingly.

ADDITIONAL INFORMATION: NPRR1013 and the associated documents can be found on the ERCOT website.

Please review the ERCOT website for previous Market Notices related to this subject.

CONTACT: If you have any questions, please contact your ERCOT Account Manager. You may also call the general ERCOT Client Services phone number at (512) 248-3900 or contact ERCOT Client Services via email at ClientServices@ercot.com.

If you are receiving email from a public ERCOT distribution list that you no longer wish to receive, please follow this link in order to unsubscribe from this list: http://lists.ercot.com.

 

dg