NOTICE DATE: January 5, 2023
NOTICE TYPE: M-A010523-01 CRR
SHORT DESCRIPTION: Update to the CRR Network Models for the 2023.FEB.Monthly.Auction and the 2024.2nd6.AnnualAuction.Seq4
INTENDED AUDIENCE: CRR Account Holders and Counter-Parties
DAYS AFFECTED: January 5, 2023
LONG DESCRIPTION: ERCOT has posted updated Congestion Revenue Right (CRR) Auction Network Models for the 2023.FEB.Monthly.Auction and the 2024.2nd6.AnnualAuction.Seq4. These updates were made to replace incorrect elements in the Bearkat (BEARKT) and West Texas Export (WESTEX) Generic Transmission Constraints (GTCs).
- Device added to the BEARKT GTC for 2023.FEB.Monthly.Auction and all six months of 2024.2nd6.AnnualAuction.Seq4:
Device Name
|
Device Type
|
Direction
|
59902 SAND_BL 59907 BERNOUL 1
|
LINE
|
-1
|
- Device removed from the BEARKT GTC for 2023.FEB.Monthly.Auction and all six months of 2024.2nd6.AnnualAuction.Seq4:
Device Name
|
Device Type
|
Direction
|
59903 BEARKAT 59907 BERNOUL 1
|
LINE
|
1
|
- The changes to the WESTEX GTC for the 2023.FEB.Monthly.Auction are summarized in the following table (device type and direction are the same as the original for all elements):
Original Device Name
|
Corrected Device Name
|
1421 WILLOWCK 60515 CLEARCR 2
|
1421 WILLOWCK 11417 THOMPRC 1
|
1444 BROWN_5 3422 KILL_SS_ 1
|
3348 RUSSELLG 903395 KILL_S 1
|
- The changes to the WESTEX GTC for the 2024.2nd6.AnnualAuction.Seq4 are summarized in the following table (device type and direction are the same as the original for all elements):
Original Device Name
|
Corrected Device Name
|
Month
|
1421 WILLOWCK 60515 CLEARCR 2
|
1421 WILLOWCK 11417 THOMPRC 1
|
All six months
|
1444 BROWN_5 3422 KILL_SS_ 1
|
3348 RUSSELLG 903445 KILL_S 1
|
JUL
|
1444 BROWN_5 3422 KILL_SS_ 1
|
3348 RUSSELLG 908755 KILL_S 1
|
AUG
|
1444 BROWN_5 3422 KILL_SS_ 1
|
3348 RUSSELLG 901193 KILL_S 1
|
SEP
|
1444 BROWN_5 3422 KILL_SS_ 1
|
3348 RUSSELLG 906514 KILL_S 1
|
OCT
|
1444 BROWN_5 3422 KILL_SS_ 1
|
3348 RUSSELLG 901814 KILL_S 1
|
NOV
|
1444 BROWN_5 3422 KILL_SS_ 1
|
3348 RUSSELLG 905299 KILL_S 1
|
DEC
|
The updated models are available in the CRR application and on the Market Information System (MIS) Secure Area.
CONTACT: If you have any questions, please contact your ERCOT Account Manager. You may also call the general ERCOT Client Services phone number at (512) 248-3900 or contact ERCOT Client Services via email at ClientServices@ercot.com.
If you are receiving email from a public ERCOT distribution list that you no longer wish to receive, please follow this link to unsubscribe from this list: http://lists.ercot.com.
mm