PRR776

Summary

Title Automatic MCPE Adjustment During Intervals of Non-Spinning Reserve Service Deployment
Next Group
Next Step
Status Approved on 03/17/2009

Action

Date Gov Body Action Taken Next steps
03/17/2009 BOARD Approved
02/17/2009 BOARD Remanded TAC Consideration
02/05/2009 TAC TAC consideration
01/08/2009 TAC Deferred/Tabled TAC Consideration
12/04/2008 TAC Deferred/Tabled TAC consideration
11/06/2008 TAC Deferred/Tabled TAC Consideration
10/23/2008 PRS Recommended for Approval TAC Consideration

Voting Record

Date Gov Body Motion Result
03/17/2009 BOARD On 3/17/09, the ERCOT Board approved PRR776 as amended by document "776PRR-63 Failed PRR Vote 030509" and as revised by the ERCOT Board. Passed
02/17/2009 BOARD Remand the TIEC appeal back to TAC with direction that a resolution be brought back to the March 17th ERCOT Board meeting. Passed
02/05/2009 TAC To recommend approval of PRR776 as amended by the 2/4/09 TIEC comments and 2/3/09 DB Energy comments and as revised by TAC Failed
01/08/2009 TAC To table PRR776 until the February 5th TAC meeting with direction that the PRR776 Discussion Group discuss issues surrounding PRR776 including ERCOT’s concerns on the use of Non-Spinning reserves in the Balancing Energy Bid Stack with respect to North American Electric Reliability Corporation (NERC) standards and resolve mechanical issues such as those raised in the 1/7/09 Luminant comments. Passed
12/04/2008 TAC To table until January 8th TAC meeting. Passed
11/06/2008 TAC To table PRR776 until the December 4th TAC meeting. Passed
10/23/2008 PRS To grant Urgent status Passed

Background

Status: Approved
Date Posted: Aug 25, 2008
Sponsor: Texas Industrial Energy Consumers (TIEC)
Urgent: Yes
Sections: 6.8.1.12, 6.9.5.1
Description: This Protocol Revision Request (PRR) adjusts the Market Clearing Price of Energy (MCPE) when the deployment of NSRS occurs to provide accurate prices in Real Time through an automatic $100/MWh upward adjustment. The $100 MCPE adjustment would replace the current PRR650, Balancing Energy Price Adjustment Due to Non-Spinning Reserve Service Energy Deployment, method of removing NSRS deployments and manually re-running Scheduling, Pricing, and Dispatching (SPD). The $100 adjustment is based on the average MCPE adjustment during NSRS deployments since 01/01/07.
Reason: After-the-fact price adjustments resulting from PRR650 prevent price-responsive loads from reacting to prices in Real Time.

Key Documents

Related Content